Points To Be Considered Before Installation Of The Device

Water treatment system’s operating water temperature is between minimum 5°C (41°F) and maxi-mum 60°C (140° F). It has risk of freezing to operate the device below 5°C as it carries risk of damage to filters when operated at above 40°C.

It is necessary to select a suitable location first for installation of water treatment device. It must be considered during selection that installation place should be close to cold water line of the RO device and to the drainage and sufficient space should be left for working in case of malfunction and filter replacement.

Water treatment device is designed for water with specifications close to tap water, whose inlet conductivity is max. 600 ppm and the turbidity is max 3 NTU. If raw water source and specifications are unknown, the raw water should be sent for analysis before installation of the device in order to check the suitability.

If the device is used beyond the limit values mentioned in technical specification part of the users’ manual, the requested quality will not be achieved for product water. Usage of such feed water will cause variation in replacement periods of filters and membrane.

Inlet pressure is between 3 – 6 bar for water treatment devices without pump and between 1- 6 bar for water treatment devices with pump. The optimum working pressure is 3 bar. In case the inlet pressure is above 4 bar, it is recommended to install a pressure reducer to prevent more wastewater discharge. Do not connect the device to power socket before it is installed. Our company will not be liable for any problems caused by non-observance of the above warnings.

Technical Specification

Filter Cartriges

Manual Installation And Assembly

Membrane Installation

After intalling the filters, unscrew membrane housing cap. Insert the membrane into the housing until it stops. Then, screw the housing cap.

Cut the tube to a length thatwill allowto con-nect the post carbon filter outlet to the faucet after mounting the faucet and drain line.

Loosen and pull out stem-nut on outlet of the post carbon filter. Put the nut on tube and tighten firmly. Insert the other side of the tube into res-pectively yellow nut and collet placed under the faucet. Push the tube to the faucet and tighten the nut firmly.